Manitowoc Ice E-0600 installation instructions Bin Control Setting

Models: E-0600

1 2
Download 2 pages 61.49 Kb
Page 2
Image 2

D.Put the damper door, which was rem oved on an earlier step, in the ice chute. Rotate the dam per door. With the door in the open position, the counterweight should trip th e micro-switch lever. When you hear the micro-switch

giving a clicking sound, y ou know the door is operating properly . If y ou don’t hear the switch clicking, loosen the screws on the switch housing and move it closer to the counterweight.

E. To install the center ice chute “B”, the widest part of the chute is the top, and the flanged side should face the front of the ice m achine. Insert the top of the center ice chute into the lower m achine ice compartment and slide the top of the chute into the upper m achine ice chute opening from the bottom until it clears ice chute “A”. After it clears the lower ice chute, let it sit on the chute and proceed to step F.

F.Place upper ice chute “C” into ice chute opening of the top ice machine base. Make sure the bin control bulb has clearance between the base opening and ice chute.

G.Place damper door in ice chute. Make sure the damper door trips the micro-switch when opened. If not, return to part 3, step D.

H.The center chute “B” fits over the outside of the upper chute. From inside the lower ice compartment, slide center ice chute “B” onto the upper chute “C”. Fasten center chute to the upper chute with four sheet metal screws.

I.Take the bottom of the center chute and align the rivnuts on th e sides of the chute with the slots on the side of ice chute “A”. The bottom of the center chute fits on the in side of the lower chute. Take a knurled m achine screw and a lock washer and place in slot on lower chute. Tighten screw into rivnut.

J. Place center chute cover “D” on center chute and screw in place with ten sheet m etal screws. Drive six screws through the cover into center chute, two screws into upper chute, two screws into lower chute.

K.Replace water pump in lower ice machine (see part 3, step A).

4.Bin Control Setting:

A. The top machine should shut off when the ice level in th e storage bin reaches the bulb. If the top machine shuts

off with the ice level in the bin above the control bul

b, turn the black knob m arked colder counterclockwise

approximately 1/4 turn. If the ice level is below the bul

b when the top ice m achine shuts off, turn the knob 1/4

turn clockwise.

 

B.Proceed to service manual for electrical and water hook-up and start-up procedure. Parts List

Part Number Description

Quantity

Required

 

 

 

 

 

6555414

Lower Ice Chute Assembly

1

6820824

Center Ice Chute Assembly

1

6555714

Upper Ice Chute Assembly

1

157481

Center Ice Chute Cover

1

5124641

#8 Sheet Metal Screws, Type B

20

5544591

#8 Shakeproof Lock Washers

20

5012041

Knurled Machine Screws

2

2350041

Ranco Bin Thermostat Control w/Bracket

1

302461 Bulb

Bracket

 

 

1

5650031 Plastic

Clamps

 

 

4

6026444

Top Cover Assy.

 

 

1

8000893 Sheet 2 of 2 Rev. 06/06/01