Q-0600 Compressor Replacement

Installation Instructions

NOTE: THIS REPLACEMENT IS ONLY FOR THE Q-SERIES MACHINES. NO CHANGES WITH START/RUN COMPONENTS ARE NEEDED.

1.Disconnect power to the ice machine at the electrical disconnect (moving the toggle switch to the off position will not disconnect line voltage).

2.Remove panels (top, front, left and right sides).

3.Recover refrigerant from ice machine.

4.Remove right side corner post (when facing the front of the machine) and back panel.

8.Remove extra section of suction service valve process tube from the ice machine at swedge joint. Repeat this procedure with discharge line. Remove up to T section.

T Section

5.Remove wiring from compressor terminals.

6.Cut tubing (suction, discharge, and process lines) at the compressor ports.

7.Remove compressor from machine. Make sure to crimp and braze shut ports to compressor.

Discharge

Swedge Joint

9. Insert new compressor into the machine as shown.

Suction

Process

Manitowoc Ice, Inc.

 

2110 South 26 Street, P.O. Box 1720, Manitowoc, WI 54221-1720 USA

8006173

Telephone 920-682-0161, Fax - Sales: 920-683-7589, Service/Parts: 920-683-7585, Other: 920-683-7879

Sheet 1 of 3

Web Site - www.manitowocice.com

06/25/01

Page 1
Image 1
Manitowoc Ice Q-0600 installation instructions Compressor Replacement, Installation Instructions