5.) The correct bias reading in
If, however, the
7.) Locate the 1/4'' round hole in the bottom cover, near the front group of ventilation slots.
8.) Make sure the amp is in
9.) Slowly rotate the screwdriver while watching the meter reading. The meter may be in either "read bias" tip jack. Clockwise increases
TUBE REPLACEMENT:
Should the 300B tubes require replacement (or the originals are not returned to their proper sockets), make sure both bias adjust trimmers are turned fully clockwise before applying power to the amp. Then follow the bias procedure outlined above. The bias should be checked daily on a new set of tubes for the first week of operation. Remember to let the amp warm up for
FUSES
There are two fuses in the amplifier. One is the mains fuse located in the AC input module on the rear panel. The other is a
The internal B+ fuse is a 400mA 3AG ceramic body type unit. If this fuse blows, the tube filaments and badge lamp will ligth up, but no sound will be heard since the high voltage will be absent. If this fuse fails, it indicates trouble which will generally require technical attention. Contact your dealer or Manley Laboratories if this problem should develop.
Caution ! High voltages and high energy storage makes opening the amplifier enclosure hazardous for any uninformed person ! Call us or your dealer for specific instructions or for answers to any questions.