MANLEY 75 / 150 SE / PP 807 TRIODE MONOBLOCK
F
H 2
HH
13
A B C D E
1 2 3 4 | M |
5 6 7 8 | |
H | H |
4 | 5 |
J
I
G
H 7
HH
68
1 | 2 | 3 |
4 | N | 5 | 6 | 7 | 8 |
K
Amplifier Overhead View
L
ARCA Input Jack
BSpeaker Terminals
CB PLUS FUSE - Replace only with same type and value (MDL 1.5)
DMains fuse - Replace only with same type and value
EIEC Mains socket
FOutput Transformer
GPower Transformer
HPower Tube 807 s
IInput Tube 5751
JDriver Tube 7044
K
LPower Switch
MBias Adjustment Trimmers (each 807 has a trim and test point numbered)
NBias Test Points (Black test point is Ground)
REPLACING FUSES & LAMPS
The fuses are accessable without removing any panels. Be sure the IEC AC power cable is removed before checking the Mains Fuse. Often a bad fuse will look blackened internally but occasionally will look OK. Replace only with the same type and rating ! For 100 or 120 volt countries the fuse should be a 10 AMP
Before removing the B+ Fuse let the power supply fully discharge - this will take at least 1 minute. The cap is removed with a proper sized screwdriver and 1/4 turn
The indicator is a fuse style lamp 1.25" X .25", 8 volt, 0.3 amp. The bottom must be removed to access the lamp. Again, wait until the supply discharges.
BIAS ADJUSTMENT TRIMMERS
See the next page for full details - Read the voltage between the black test point and each of the numbered red points. If the reading is not 0.340 volts or 340 mV then adjust the corresponding numbered trimmer.