ALM100 User's Manual
Sounder Colla
r
Volume Control Shutte
r
Volume Control Baffle Plate
A
LM100 Alarm Module
Volume Control Screw
A
LM100 Faceplate
F
acep
l
a
t
e
Gas
k
e
t
Sounder Gasket
A
LM100 Mounting Screws (x2)
NMEA 2000 Cable (not
included
)
Faceplate
Mounting Screws
(x2)
Figure 2 – Flush Mounting the ALM100 Directly to a Wall
The following instructions apply wither mounting the ALM100 into an electrical box or to a wall:
1) Connect the NMEA 2000 cable to the connector on the ALM100 Alarm Module
2) Using the included ALM100 mounting screws, mount the ALM100 Alarm Module to the
wall or electrical box
3) Place the sounder gasket over the sounder on the ALM100 alarm module
4) Place the faceplate gasket over the ALM100 alarm module
5) Mount the ALM100 faceplate over the ALM100 alarm module using the included
faceplate mounting screws.
6) Screw the sounder collar onto the sounder of the ALM100 alarm module, which should
now be protruding through the large hole in the faceplate, and tighten until snug.
7) Optionally, you may install the volume control by first placing the volume control baffle
plate over the front of the sounder, then placing the volume control shutter over the
volume control baffle plate, and finally attaching both to the sounder by threading the
volume control screw into the hole in the center of the sounder.
2.4 Connecting the ALM100
The ALM100 requires a single type of electrical connection: the NMEA 2000® connection (refer
to Section 2.4.1).

2.4.1 NMEA 2000® Connection

The NMEA 2000® connector can be found on the rear of the enclosure. The NMEA 2000®
connector is a round five pin male connector (see Figure 3). You connect the ALM100 to an

Page A4 Appendix A – NMEA 2000 Interfacing Revision 1.0