DCM100 User’s Manual

Page 14 Revision 1.0

automatically void the warranty. If service is required, please return the unit to an authorized
Maretron service location.
8 Technical Specifications
As Maretron is constantly improving its products, all specifications are subject to change
without notice. Maretron products are designed to be accurate and reliable; however, they
should be used only as aids to navigation and not as a replacement for traditional navigation
aids and techniques.
Certifications
Parameter Comment
NMEA 2000
®
Level A
Maritime Navigation and Radiocommunication Equipment & Systems IEC 60945
FCC and CE Mark Electromagnetic Compatibility
NMEA 2000® Parameter Group Numbers (PGNs)
Description PGN # PGN Name Default Rate
Periodic Data PGNs 127506 DC Detailed Status 0.67 times/second
127508 Battery Status 0.67 times/second
127513 Battery Configuration Status N/A
Response to Requested PGNs 126464 PGN List (Transmit and Receive) N/A
126996 Product Information N/A
126998 Configuration Information N/A
Protocol PGNs 059392 ISO Acknowledge N/A
059904 ISO Request N/A
060928 ISO Address Claim N/A
065240 ISO Address Command N/A
126208 NMEA N/A
Maretron Proprietary PGNs 128720 Configuration N/A
Electrical
Parameter Value Comment
Operating Voltage 9 to 16 Volts DC Voltage
Power Consumption 70 mA
30 mA
VPWR+, VPWR-
NMEA 2000 Interface
Load Equivalence Number (LEN) 1 NMEA 2000
®
Spec. (1LEN = 50 mA)
Reverse Battery Protection Yes Indefinitely
Load Dump Protection Yes Energy Rated per SAE J1113
Mechanical
Parameter Value Comment
Size 3.50” x 4.20” x 2.03”
(88.9mm x 106.7mm x
51.6mm)
Including Flanges for Mounting
Weight 13 oz. (368.5 g)