TLM100 User’s Manual
TLM100 Interface Component
Threaded Tank Fitting
Threaded Adapter
TLM100 Gasket
TLM100 Sensor Component
Mounting Screws (x5)
Figure 4 – TLM100 Mounting With Threaded Adapter
2.4.1.5 Installation on a Tank with a 1.25”BSP or 1.5”NPT Threaded Tank Fitting and
Focus Tube
If a focus tube is used for a tank with a SAE J1810 5-bolt fitting, determine the depth of the
tank at the location of the tank sensor mounting hole and use a saw with a metal-cutting blade
to trim the focus tube so that it reaches 1” above the tank bottom when mounted. Remove any
burrs from the end of the focus tube after trimming.
For a threaded tank sender mounting hole, first thread the adapter into the tank opening and
tighten to a torque of 3-5 ft-lbs (4.1-6.8 N·m).
Next, place the TLM100 gasket over the adapter so that the bolt holes on the gasket line up
with the bolt holes on the adapter (WARNING – the gasket must be properly aligned; it only fits
one way). Place the TLM100 sensor component on top of the adapter so that the bolt holes on
the TLM100 sensor component line up with the bolt holes on the adapter.
Place the included mounting screws through the bolt holes on the TLM100 sensor component,
and thread them into the adapter, tightening them to a torque of 10-15 in-lbs (1.1-1.7 N·m). Do
not use threadlocking compounds containing methacrylate ester, such as Loctite Red (271), as
they will cause stress cracking of the plastic enclosure.
Page 8 Revision 1.3