![GAS APPLIANCE INSTALLATION](/images/new-backgrounds/46297/4629747x1.webp)
GAS APPLIANCE INSTALLATION
TRIM INSTALLATION
The face of your fireplace may be left exposed or trimmed with any noncombustible material such as brick, stone or marble. See Figure 28. If a noncombustible trim is installed, be sure it is fastened snugly to the face of the fireplace. A crack between the material and the face of the fireplace could pose a fire hazard and impair the proper operation of the fireplace. Blocking the fireplace with framing and attaching the base to the supporting floor will reduce the possibility of such a crack developing.
CAUTION: Do not allow any trim materials to extend closer than
Wall ties should be fastened to the face of the fireplace with sheet metal screws and placed in the mortar joints of masonry trim.
Combustible material must not be installed below the top spacers of the fireplace or overlap the sides of the fireplace face. Seal the face of the fireplace to the surrounding wall with
CAUTION: No trim should block or restrict in any way the flow of air into the air inlets in the face of the fireplace. See Figures 28 and 29
Be sure to provide the required floor protection as described in a preceeding section of this manual. (See Figure 10).
GLASS DOOR INSTALLATION
This fireplace has been tested and listed for use with Model MGD36B or MGD36PB glass doors. For installa- tion of the Model MGD36B or MGD36PB glass doors, see the instructions provided with the doors.
24