Start Your Appliance

To start your appliance, plug it into a power supply. Push and hold the “ON/OFF” button located on the display panel for three (3) seconds (see Figure 3).

NOTE: The unit may take 5 to 10 minutes to start.

Once the bottles are loaded, allow at least 48 hours for the unit to stabilize before making any adjustments to the initial setting.

Set the Controls

The available temperature range of the unit is from 40 to 65 degrees F. The middle range on the control is approxi- mately 55 degrees F. The temperature can be lowered or raised by first pushing and holding the “SET” button for one (1) second on the display pad. You will enter Tem- perature SET MODE. Pushing either the “WARMER” or “COLDER” key while holding the “SET” key will raise or lower the set temperature by one (1) degree F. Releasing the “SET” key exits SET MODE. As with any refrigeration product, there is a slight temperature variance at different locations within the cabinet.

Adjustable Temperature Control

The temperature control is fully adjustable from the low forties to the mid sixties. The range allows flexibility of temperature preferences.

Interior Light and Switch

The interior light makes it easy to view your wine labels and enhances the display of your collection. To engage the display light feature, press the round light switch. It is lo- cated on the left side of the user panel. The light will come on and stay on with the door closed until the light switch is pressed again. The light will also come on when the door

is opened.

Alarm

F

 

 

 

 

 

 

Control

 

 

 

 

 

 

 

Set

Colder

Warmer ON/OFF

 

 

Press and Hold

 

 

Press and Hold

 

Figure 3

 

 

 

 

 

 

Information/Lockout Key

Each momentary press of the “SET” key activates the Infor- mation and Lockout selection menu. Additional presses sequentially scroll through the Information selection menu and allow the enabling and disabling of the Lockout fea- ture.

Information Selection Menu

1.Current Interior Temperature (tI): Press and hold the “SET” key to display the current interior temperature.

2.Maximum Stored Temperature (thi): Press and hold the “SET” key to display the maximum temperature stored. The data can be cleared by pressing “SET” and “ON/OFF” simultaneously while the value is displayed.

3.Minimum Stored Temperature (tLO): Press and hold the “SET” key to display the minimum temperature stored. The data can be cleared by pressing “SET” and “ON/OFF” simultaneously while the value is displayed.

4.Total Operating Time of the Condenser Since the Last Cleaning (cnd): Press and hold the “SET” key to display the total operating hours of the compressor since the last cleaning. The control stores the total operating hours of the compressor to determine the volume of air that has moved across the condenser coils. This number is displayed in weeks. A reminder is displayed when a cleaning is recommended (see Alarm Codes). The recommended cleaning period is the equivalent of one year of air volume. The data can be cleared by pressing the “SET” and “ON/OFF” keys simultaneously while the value is displayed.

5.Keypad Lockout Feature (Loc): This feature is useful for prohibiting changes in the temperature set point or accidentally turning the unit off. Press and hold the “SET” key to display the current “Loc” setting. If “No” is displayed, Lockout is OFF and all keys are enabled. If “Yes” is displayed, Lockout is ON and the “ON/ OFF”, “WARMER”, and “COLDER” keys are disabled. However, the key tones remain enabled. While hold- ing the “SET” key, press the “WARMER” or “COLDER” key to select the desired state. Release the “SET” key to confirm the selection.

NOTE: The Information/Lockout Key “SET” remains enabled regardless of the “Loc” setting.