Master Bilt 48, BMG/TMG 27, 80, 74, 52 manual Cabinet should be grounded, Electrical

Models: 52 74 48 80 BMG/TMG 27

1 17
Download 17 pages 43.57 Kb
Page 7
Image 7

ELECTRICAL

WARNING

Before servicing electrical components in the case or the doors or door frames make sure all power to case is off. Always use a qualified technician.

NOTICE

For models with electronic ballast only:

For replacement ballast, use only ballast that complies with UL Type CC rating if unit is equipped with electronic ballast.

Check voltage and amps drawn on (Page 12-15) to determine proper line and fuse or circuit breaker size. Check power supply for low voltage. If voltage reads “120” with no load, and it drops below “100 or less” when the compressor tries to start, it is an indication of too small supply wiring or too long to run.

It is recommended that a separate circuit be run for each cabinet to prevent another appliance blowing the fuse or breaker, causing loss of product.

IMPORTANT

This cabinet is pre-wired internally for 120-volt circuits. “Tapping” or feeding the 115-volt circuit from 230-volt supply may result in overloaded circuit breakers or blown fuses and damage to electrical system, thereby voiding the warranty.

The cabinet should be grounded.

7

Page 7
Image 7
Master Bilt 48, BMG/TMG 27, 80, 74, 52 manual Cabinet should be grounded, Electrical