The merchandiser must be plugged into a 115 volt, 60 HZ grounded receptacle electrical outlet with a circuit fuse or breaker. (See figure 1). The condensing unit data plate will indicate the maximum fuse/breaker size. DO NOT use extension cords. Extension cords may decrease the voltage to the unit and ultimately cause the compressor to fail.
NOTE: Some outdoor locations require ground fault interrupt (GFI) outlets. These outlets may trip upon condensing unit start. Refrigeration equipment is exempt in some areas from GFI requirements. Local electric codes should be checked.
Plug merchandiser power cord into lower receptacle of electrical outlet. The condensing unit will start, the light will illuminate on glass door models, and unit cooler evaporator fans will start on
2.Temperature Control: Cabinet temperature is maintained by cycling the condensing unit automatically with a thermostat. On
The temperature is adjusted by turning the control knob. Turning the control knob fully counterclockwise will shut off power to compressor. DO NOT readjusts the internal adjustments of the control without consulting factory.