Master Bilt TEM-4-24, TEM-4-30, TEM-6-24, TEM-5-24, TEM-5-30, TEM-3-30, TEM-3-24 Modules Required

Models: TEL-5-30 TEL-3-24 TEL-3-30 TEL-4-24 TEL-2-30 TEL-4-30 TEL-5-24 TEL-6-24 TEM-2-30 TEM-3-24 TEM-3-30 TEM-5-30 TEM-4-24 TEM-5-24 TEM-6-24 TEM-4-30

1 6
Download 6 pages 35.72 Kb
Page 3
Image 3
MODULES REQUIRED

MODULES REQUIRED FOR 24" WIDE DOOR LINEUPS & BTU PERFORMANCE DATA

 

MODULES REQUIRED

TOTAL OVERALL

+20°F SUCTION MIN.

-11°F SUCTION MIN.

-18°F SUCTION MIN.

 

BTUs (75°F STORE,

BTUs (75°F STORE,

BTUs (75°F STORE,

 

LENGTH

NO. OF

3

4

5

6

WITH ONE PAIR

55% RH, +35°F AVER-

55% RH, -3°F AVER-

55% RH, -12°F AVER-

DOORS

DOOR

DOOR

DOOR

DOOR

OF 2" ENDS

AGE PRODUCT TEMP.)

AGE PRODUCT TEMP.)

AGE PRODUCT TEMP.)

3

1

 

 

 

781/4"

3750

4750

5125

4

 

1

 

 

102"

4600

6150

6550

5

 

 

1

 

1253/4"

5750

7625

8300

6

 

 

 

1

1491/2"

6900

9150

9960

7

1

1

 

 

1761/4"

8050

10,675

11,620

8

 

2

 

 

200"

9200

12,200

13,280

9

 

1

1

 

2233/4"

10,350

13,725

14,940

10

 

 

2

 

2471/2"

11,500

15,250

16,600

11

 

 

1

1

2711/4"

12,650

16,775

18,260

12

 

 

 

2

295"

13,800

18,300

19,920

13

 

2

1

 

3213/4"

14,950

19,825

21,580

14

 

2

 

1

3451/2"

16,100

21,350

23,240

15

 

 

3

 

3691/4"

17,250

22,875

24,900

16

 

4

 

 

396"

18,400

24,400

26,560

17

 

 

1

2

4163/4"

19,550

25,925

28,220

18

 

 

 

3

4401/2"

20,700

27,450

29,880

19

 

1

3

 

4671/4"

21,850

28,975

31,540

20

 

 

4

 

491"

23,000

30,500

33,200

21

1

 

 

3

5143/4"

24,150

32,025

34,860

22

 

1

 

3

5381/2"

25,300

33,550

36,520

23

 

 

1

3

5621/4"

26,450

35,075

38,180

24

 

 

 

4

586"

27,600

36,600

39,840

25

 

 

5

 

6123/4"

28,750

38,125

41,500

MODULES REQUIRED FOR 30" WIDE DOOR LINEUPS & BTU PERFORMANCE DATA

 

MODULES REQUIRED

TOTAL OVERALL

+20°F SUCTION MIN.

-11°F SUCTION MIN.

-18°F SUCTION MIN.

 

BTUs (75°F STORE,

BTUs (75°F STORE,

BTUs (75°F STORE,

 

LENGTH

NO. OF

2

3

4

5

WITH ONE PAIR

55% RH, +35°F AVER-

55% RH, -3°F AVER-

55% RH, -12°F AVER-

DOORS

DOOR

DOOR

DOOR

DOOR

OF 2" ENDS

AGE PRODUCT TEMP.)

AGE PRODUCT TEMP.)

AGE PRODUCT TEMP.)

2

1

 

 

 

671/2"

2800

3300

3550

3

 

1

 

 

981/2"

3750

4750

5125

4

 

 

1

 

1281/2"

4600

6150

6550

5

 

 

 

1

159"

5750

7625

8300

6

 

2

 

 

193"

6900

9150

9960

7

1

 

 

1

2221/2"

8050

10,675

11,620

8

 

1

 

1

2531/2"

9200

12,200

13,280

9

 

 

1

1

2831/2"

10,350

13,725

14,940

10

 

 

 

2

314"

11,500

15,250

16,600

11

 

2

 

1

348"

12,650

16,775

18,260

12

1

 

 

2

3771/2"

13,800

18,300

19,920

13

 

1

 

2

4081/2"

14,950

19,825

21,580

14

 

 

1

2

4381/2"

16,100

21,350

23,240

15

 

 

 

3

469"

17,250

22,875

24,900

16

 

2

 

2

503"

18,400

24,400

26,560

17

1

 

 

3

5321/2"

19,550

25,925

28,220

18

 

1

 

3

5631/2"

20,700

27,450

29,880

19

 

 

1

3

5931/2"

21,850

28,975

31,540

20

 

 

 

4

624"

23,000

30,500

33,200

21

 

2

 

3

658"

24,150

32,025

34,860

22

1

 

 

4

6871/2"

25,300

33,550

36,520

23

 

1

 

4

7181/2"

26,450

35,075

38,180

24

 

 

1

4

7481/2"

27,600

36,600

39,840

25

 

 

 

5

779"

28,750

38,125

41,500

3

Page 3
Image 3