Connecting the LP Tank

ALL INSTRUCTIONS AND SAFEGUARDS ON THIS PAGE MUST BE

FOLLOWED TO PREVENT FIRE, DAMAGE, AND / OR INJURY.

1. The knob on the LP tank must be closed. See that the knob is turned clockwise to a full stop.

2. Check that the control knob on the smoker is turned off.

3. Remove the protective cap from the LP tank valve and coupling nut, if present.

4. Hold the regulator in one hand and insert the nipple into the valve outlet. Be sure the nipple is centered in the valve outlet. The coupling nut connects to the large outside threads on the valve outlet. Use care - do not cross thread the connection.

5. Hand tighten the coupling nut clockwise until it comes to a full stop. Firmly tighten by hand only. Do not use tools.

CAUTION: In the connection process, the HVR side of the connection will seal on the back check in the valve, resulting in a slight resistance. The connection requires about one-half to three-quarters additional turn to complete the connection.

Any fuel supply cylinder used must be constructed and marked in accordance with specifications for propane cylinders of the U.S. Department of Transportation (DOT) CFR 49, or CAN/CSA B339. The appliances is to be used only with the 20 pound, vertical standing vapor withdrawal type tank.

(A) Do not store tanks under or near the smoker.

(B) Never fill tanks more than 80% full.

If instructions A and B above are not followed exactly, a fire causing death or serious injury may occur.

This smoker is designed to operate on LP (Liquefied Propane) gas only.

The 20 lb LP cylinder used with this smoker must conform to the following requirements. Diameter- 12” (30.5cm)

Height 18” (45.7cm)

With a maximum capacity of 20 pounds

The gas cylinder used must include a collar to protect the cylinder valve. The cylinder supply system must be arranged for vapor withdrawal.

The instructions stated on gas cylinder tanks have to be followed when filling or transporting tanks. Failure to do so could result in problems relating to overfilling, excessive venting release of gas and to regulator freezing.

Do not allow dirt or foreign material to get into or onto tank connection when it is not attached to the fuel supply system. Place the dust cap on cylinder valve outlet whenever the cylinder is not in use. Only install the type of dust cap on the cylinder valve outlet that is provided with the cylinder valve. Other types of caps or plugs may result in leakage of propane.

17

Page 17
Image 17
Master Cookware 3405GT, 3405GW, 3605G, 3405BGW, 2505G, 3005G owner manual Connecting the LP Tank

3405BG, 3005G, 2505G, 3405G, 3405BGW specifications

Master Cookware has established itself as a leader in the kitchenware industry, and the latest additions to their lineup are the Master Cookware models 3405GW, 3405GT, 3605G, 3405BGW, and 3405G. These models are designed to satisfy the needs of both amateur cooks and professional chefs, offering a combination of innovative technology and robust construction.

The Master Cookware 3405GW and 3405GT are particularly notable for their advanced non-stick surfaces. Utilizing a three-layer Teflon coating, these pans ensure food releases easily, minimizing the need for excessive oils and fats. This feature not only promotes healthier cooking options but also makes cleaning up a breeze. Both models come with ergonomic handles that are heat resistant, providing users with a secure and comfortable grip while cooking.

The 3605G model elevates design with its spacious interior and even heat distribution properties. This model boasts a heavier gauge aluminum body, ideal for achieving perfect sears and browning. The 3605G also features a tempered glass lid that allows for easy monitoring of food, while retaining moisture and flavor.

For those seeking style along with functionality, the 3405BGW excels with its glossy finish and vibrant colors, making it a striking addition to any kitchen decor. This model retains all the superior features of the other lines, including the non-stick technology and ergonomic handles.

Lastly, the Master Cookware 3405G model focuses on durability and versatility. It is compatible with all cooktops, including induction, and is oven-safe up to 500°F, making it an ideal choice for recipes that require both stovetop and oven cooking.

Overall, the Master Cookware collection—from the 3405GW to the 3605G—exemplifies quality and innovation. Their user-friendly features, including heat resistance and even cooking, cater to all cooking enthusiasts. Whether searing, sautéing, or baking, these pieces will undoubtedly enhance the cooking experience while ensuring delectable results. With Master Cookware, cooking becomes not just a necessity, but a delightful culinary adventure.