Master Lock 150000 BTU/Hr Trouble- Shooting, Observed Fault Possible Cause, WARNING High voltage

Models: 100000 BTU/Hr 70000 BTU/Hr 150000 BTU/Hr

1 24
Download 24 pages 32.88 Kb
Page 9
Image 9
TROUBLE- SHOOTING

TROUBLE- SHOOTING

OBSERVED FAULT POSSIBLE CAUSEWARNING

Never service heater while it is plugged in, operating, or hot. Severe burns and electrical shock can occur.

OBSERVED FAULT POSSIBLE CAUSE

REMEDY

Heater ignites, but flame-out control shuts off heater after a short period of time

Wrong pump pressure

See Pump Pressure

 

Adjustment, page 12.

Dirty air output, air intake,

See Air Output, Air Intake

and lint filters

and Lint Filters, page 12.

Dirty fuel filter

See Fuel Filter, pages 10

 

and 11.

Dirt in nozzle

See Nozzle, page 13.

Dirty photocell lens

Clean photocell lens.

Bad flame-out control

Replace flame-out control.

Heater will not ignite, but motor runs for a short period of time.

Wrong pump pressure

See Pump Pressure

 

Adjustment, page 12.

Carbon deposits on spark

See Spark Plug, page 11.

plug and/or improper gap

 

Dirty fuel filter

See Fuel Filter, pages 10

 

and 11.

Dirt in nozzle

See Nozzle, page 13.

Water in fuel tank

Drain and flush fuel tank

 

with clean kerosene. See

 

Storage, page 8.

WARNING: High voltage!

Electronic ignitor not

Make sure electronic

grounded (earthed)

Bad electronic ignitor

ignitor mounting is tight.

 

Replace electronic ignitor.

Motor does not start

Flame-out control not reset

Reset flame-out control

when heater is

 

button, see Figures 6 and

plugged in, fan

 

7, page 7.

rotates slowly or

Binding pump rotor

If fan is hard to turn, see

does not turn.

 

Pump Rotor, page 14.

 

 

9

101585

Page 9
Image 9
Master Lock 150000 BTU/Hr Trouble- Shooting, Observed Fault Possible Cause, WARNING High voltage, See Pump Pressure