![BATTERY DISCHARGE LAMP](/images/new-backgrounds/88754/8875417x1.webp)
GENERATOR FEATURES
Continued
Oil Alert
Lamp
OIL
CHARGE
OFF
Battery
Discharge
Lamp
Figure 2 - Battery Discharge Lamp and Oil Alert Lamp Location
BATTERY DISCHARGE LAMP
The battery discharge lamp (see Figure 2, above) will light if battery charger is not operating while engine is running. If this happens, the battery will not charge and will eventually run down. Have battery charging circuit repaired by authorized service person.
FULL POWER SELECTOR SWITCH
The full power selector switch is on the control panel. The switch has two posi- tions: 120 VOLT ONLY, and 120/240 VOLT.
120 VOLT ONLY: This position sends full power to the 120V receptacles only. 240V power is not available. Use this position when powering 120V items only.
120/240 VOLT: This position sends full power to the 120/240V receptacle. It also powers the 120V receptacles at reduced wattage capacity.
FULL POWER | FULL POWER |
SELECTOR | SELECTOR |
120V | 120 | 120V | 120 |
ONLY | 240V | ONLY | 240V |
120 VOLT ONLY | 120/240 VOLT |
Position | Position |
Figure 3 - Full Power Selector Switch
IMPORTANT: Do not move the full power selector switch while powering electrical items. Unplug all items before moving switch. Failure to do so can damage switch.
Continued 9