REGULATOR TO GAS CYLINDER VALVE CONNECTION
SOAPY WATER TEST WARNING AND PROCEDURES
CLOCKWISE
COUNTER
• The Soapy Water Test must be performed each time the gas cylinder |
CLOCKWISE
OnOFF
WARNING
Extinguish all open flames
before connecting the
regulator to the gas cylinder.
is connected to your grill or each time the grill is used. |
• The Soapy Water Test must be performed outdoors in a |
area. |
• When performing the Soapy Water Test, always keep grill away from |
open flames, sparks, or lit cigarettes. Never use an open flame to test |
for gas leaks. |
• This product will not operate with natural gas. |
PROCEDURE:
CONNECTION
TO GAS CYLINDER
GAS CONTROL VALVE OPERATIONS
1.Turn gas control valve to OFF position, and turn the gas cylinder valve to the OFF position.
2.Prepare your soapy water solution by combining (1) one part dish washing liquid with (3) three parts water to test for the possibility of any gas leaks in the hose or connections to regulator and the regulator connection to gas cylinder. Apply soapy water solution to the
gas cylinder valve, regulator and up the hose to the grill hose connection.
3.Turn gas cylinder valve ON (gas control valve is in the OFF position) and observe gas cylinder valve for bubbles. DO NOT LEAVE GAS ON FOR MORE THAN 12 SECONDS. If bubbles appear, stop, turn gas cylinder OFF, and retighten the fitting. Repeat test.
4.When the gas cylinder valve has been tested, and there are no leaks, wait a minimum of 5 minutes for gas fumes to diminish before lighting cooker.
DURING ANY PORTION OF THE SOAPY WATER TEST, IF BUBBLES CONTINUE TO APPEAR, STOP, DO NOT USE THE GRILL AND CONTACT YOUR LOCAL PROPANE DEALER OR MASTERBUILT AT
Before each use perform soapy
water test. Before each use,
inspect gas hose for any signs of abrasion, cuts, leaks, or wear. If replacement is needed, contact Masterbuilt Manufacturing for model #BPRLP14.
Bubbles in Soapy Water Test
4 | 5 |