2.9Environmental specifications

2.9.1Drive case temperature

Above 1,000 feet (305 meters), the maximum temperature is derated linearly to 112°F (44°C) at 10,000 feet (3,048 meters).

Drive case temperature should be measured at the location indicated in Figure 4 on page 21.

Operating (Drive case temperature)

0° to 75°C (32° to 167°F)

 

 

Nonoperating (Ambient *)

–40° to 70°C (–40° to 158°F)

 

 

* Ambient temperature is defined as the temperature of the environment immediately surrounding the drive.

2.9.2Temperature gradient

Operating:

20°C per hour (68°F per hour max), without condensation

 

 

Nonoperating:

30°C per hour (86°F per hour max)

 

 

2.9.3Humidity

2.9.3.1Relative humidity

Operating:

5% to 90% noncondensing (30% per hour max)

 

 

Nonoperating:

5% to 95% noncondensing (30% per hour max)

 

 

2.9.3.2Wet bulb temperature

Operating:

37.7°C

(99.9°F max)

 

 

 

Nonoperating:

40.0°C

(104°F max)

 

 

 

2.9.4Altitude

Operating:

–60.96 m to 3,048 m (–200 ft. to 10,000+ ft.)

 

 

Nonoperating:

–60.96 m to 12,192 m (–200 ft. to 40,000+ ft.)

 

 

Pipeline HD.2 Series SATA Product Manual, Rev. A

13

Page 19
Image 19
Maxtor ST31000322CS, ST31000424CS, ST3250312CS, ST3500312CS, ST3500414CS manual Environmental specifications