14 DiamondMax 22 Serial ATA Product Manual, Rev. A
2.8 Environmental specifications
2.8.1 Ambient temperature
Ambient temperature is defined as the temperature of the environment immediately surrounding the drive.
Actual drive case temperature should not exceed 69°C (156°F) within the operating ambient conditions.
Above 1,000 feet (305 meters), the maximum temperature is derated linearly to 112°F (44°C) at 10,000 feet
(3,048 meters).
2.8.2 Temperature gradient
2.8.3 Humidity
2.8.3.1 Relative humidity
2.8.3.2 Wet bulb temperature
2.8.4 Altitude
Operating: 0° to 60°C (32° to 140°F)
Nonoperating: –40° to 70°C (–40° to 158°F)
Operating: 20°C per hour (68°F per hour max), without condensation
Nonoperating: 30°C per hour (86°F per hour max)
Operating: 5% to 95% noncondensing (30% per hour max)
Nonoperating: 5% to 95% noncondensing (30% per hour max)
Operating: 37.7°C (99.9°F max)
Nonoperating: 40°C (104°F max)
Operating: –60.96 m to 3,048 m (–200 ft. to 10,000+ ft.)
Nonoperating: –60.96 m to 12,192 m (–200 ft. to 40,000+ ft.)