Maytag MCE8000AY Gas Connection, Testing for Gas Leaks, Altitude Orifice Part Ft M Size # Number

Models: MCE8000AY

1 58
Download 58 pages 57.41 Kb
Page 7
Image 7

Important Safety Information For proper operation at altitudes above 2,500 feet

The natural gas valve spud orifice size must be reduced to ensure complete combustion. See table.

Altitude

Orifice

Part

Ft (M)

Size #

number

3000

(915)

43

503778

6000

(1830)

44

58719

8000

(2440)

45

503779

9000

(2740)

46

503780

10000(3050)

47

503781

Gas Connection

Connect gas supply to dryer using a new stainless steel flexible connector or hard pipe (check local codes) according to illustration. Test for leaks and check burner flame after gas supply is connected.

• Dryer must be connected to type of gas as shown on nameplate located in the door recess.

• Use pipe joint compound insoluble on LP (propane) Gas, or Teflon tape, on all pipe threads.

• Purge air and sediment from gas supply line before connecting it to the dryer. Before tightening the connection, purge remaining air from gas line to dryer until odor of gas is detected. This step is required to prevent gas valve contamination.

Use a new stainless steel flexible connector only if allowed by local codes (use A.G.A. certified connector).

3/8" NPT gas connection

1/8" NPT pipe plug (for checking inlet gas pressure)

Install Equipment shut-off valve within 6' (1.8 m) of dryer.

Black iron piping:

• Shorter than 20’ (6.1 m) – use 3/8” piping

• Longer than 20’ (6.1) m) – use 1/2” piping

Testing for Gas Leaks

 

After final gas connection is made, turn on manual gas

 

 

valve and test all connections in gas supply piping for gas

 

leaks. Leak testing of the appliance shall be conducted

 

 

according to the manufacturer’s instructions.

 

 

1.

Place soap suds on connections.

 

 

2.

If bubbles appear, a leak is present. Shut off gas

 

 

 

supply valve.

 

 

3.

Tighten joint if leak is at factory fitting.

 

 

 

• If leak is not at factory fitting, unscrew, apply more

 

 

 

joint compound, and tighten to correct leak.

 

©2003 Maytag Appliances Company

16022785 Rev. 0

7

Page 7
Image 7
Maytag MCE8000AY manual Gas Connection, Testing for Gas Leaks, Altitude Orifice Part Ft M Size # Number