Maytag MDG-30 No L.E.D. light emitting diode display, Drive motor not operating does not start

Models: MDG-30

1 52
Download 52 pages 46.77 Kb
Page 41
Image 41

SECTION VII

TROUBLESHOOTING

IMPORTANT: YOU MUST DISCONNECT and LOCKOUT THE ELECTRIC SUPPLY and THE GAS SUPPLY BEFORE ANY COVERS or GUARDS ARE REMOVED FROM THE MACHINE TO ALLOWACCESS FOR CLEANING, ADJUSTING, INSTALLATION, or TESTING OFANY EQUIPMENT per OSHA(Occupational Safety and HealthAdministration) STANDARDS.

The information provided will help isolate the most probable components associated with the difficulty described. The experienced technician realizes, however, that a loose connection or broken/ shorted wire may be at fault where electrical components are concerned and not necessarily the suspected component itself.

Electrical parts should always be checked for failure before being returned to the factory.

The information provided should not be misconstrued as a handbook for use by an untrained person making repairs.

IMPORTANT: When replacing blown fuses, the replacement must be of the exact rating as the fuse being replaced.

WARNING: ALL SERVICE and TROUBLESHOOTING SHOULD BE PERFORMED BY A QUALIFIED PROFESSIONAL OR SERVICE AGENCY.

WARNING: WHILE MAKING REPAIRS, OBSERVE ALL SAFETY PRECAUTIONS DISPLAYED ON THE DRYER or SPECIFIED IN THIS MANUAL.

MICROPROCESSOR (COMPUTER) MODELS

A.No L.E.D. (light emitting diode) display

1.Service panel fuse blown or tripped breaker.

2.Blown control circuit L1 or L2 1/2-amp (Slo Blo) fuse.

3.Failed microprocessor controller (computer).

4.Failed step down transformer (for models 380 volts or higher ONLY).

B.Drive motor not operating (does not start)

1.Failed drive motor contactor (relay).

2.Failed drive motor.

37

Page 41
Image 41
Maytag MDG-30 manual No L.E.D. light emitting diode display, Drive motor not operating does not start