FIGURE 1
FIGURE 2
Remove lower screws from hinge receptacle plates. Align lower trim and reinstall screws.
NOTE: Lower trim overlaps front edge of cabinet by 9/16″.
Improper installation of the grounding circuit can result in a risk of electric shock.
Consult a qualified electrician or serviceman if the grounding instructions are not completely understood, or if doubt exists as whether the appliance is properly grounded.
SERVICE
Interrupt the source of electricity to the unit when attempting to repair or service the oven. Failure to do this could result in a dangerous or even fatal shock.
FIGURE 3 Sample Template -- not to scale
ELECTRICAL CONNECTIONS
Unit to be properly circuit protected and wired according to local electrical code and National Electrical Code.
It is advisable that the electrical wiring and hookup be accomplished by a competent electrician.
120/240 VAC or 120/208 VAC 60 Hz. See serial plate on each unit for power requirements.
The neutral of the lower unit is grounded to the frame through the green or solid grounding wire. (The green and the white wires are twisted together at the termination of the conduit.) If used on new
The chart below recommends the minimum circuit protection and wire size if the appliance is the only unit on the circuit.
|
|
| RECOMMENDED MINIMUM |
|
K.W. RATING | CIRCUIT PROTECTION | WIRE SIZE | ||
ON SERIAL PLATE | IN AMPRES | (AWG) | ||
|
|
|
|
|
0 | 4.8 | 20 | 12 | |
4.9 | 6.9 | 30 | 10 | |
7.0 | 9.9 | 40 | 8 | |
10.0 | 11.9 | 50 | 8 | |
12.0 | 60 | 6 |