Remove lower screws from hinge receptacle plates. Align lower trim and reinstall screws.

NOTE: Lower trim overlaps front edge of cabinet by 9/16.

Improper installation of the grounding circuit can result in a risk of electric shock.

Consult a qualified electrician or serviceman if the grounding instructions are not completely understood, or if doubt exists as whether the appliance is properly grounded.

SERVICE

Interrupt the source of electricity to the unit when attempting to repair or service the oven. Failure to do this could result in a dangerous or even fatal shock.

FIGURE 3 Sample Template -- not to scale

ELECTRICAL CONNECTIONS

Unit to be properly circuit protected and wired according to local electrical code and National Electrical Code.

It is advisable that the electrical wiring and hookup be accomplished by a competent electrician.

120/240 VAC or 120/208 VAC 60 Hz. See serial plate on each unit for power requirements.

The neutral of the lower unit is grounded to the frame through the green or solid grounding wire. (The green and the white wires are twisted together at the termination of the conduit.) If used on new branch--circuit installations (1996 NEC), mobile homes, recreational vehicles, or in an area where local codes prohibit grounding through the neutral conductor, untwist or disconnect the green wire and connect the green wire to ground in accordance with local code. Connect the white neutral to the service neutral. Connect all wires to the branch circuit with approved connectors. Use copper or aluminum wire. If aluminum wire is used, use connectors recognized for joining aluminum to copper.

The chart below recommends the minimum circuit protection and wire size if the appliance is the only unit on the circuit.

 

 

 

RECOMMENDED MINIMUM

 

K.W. RATING

CIRCUIT PROTECTION

WIRE SIZE

ON SERIAL PLATE

IN AMPRES

(AWG)

 

 

 

 

 

0

--

4.8

20

12

4.9

--

6.9

30

10

7.0

--

9.9

40

8

10.0

--

11.9

50

8

12.0

-- 14.9

60

6

IMPORTANT - SAVE FOR LOCAL ELECTRICAL INSPECTOR’S USE