Maytag 99043751D, W10112419D Install Range Hood, C A Cb, For vented model installations only

Models: 99043751D

1 24
Download 24 pages 9.32 Kb
Page 9
Image 9
Install Range Hood

4.Use saber or keyhole saw to cut a 6¹⁄₄" (15.9 cm) diameter opening.

6 ¹/₄" (15.6 cm) diam.

*4³⁄₄"

(12.1 cm)

Cabinet cutouts

*From wall, not cabinet frame

5.Install vent through the vent opening in upper cabinet or wall. Complete venting system according to the selected venting method. See “Venting Requirements” section.

6.Use caulking to seal exterior wall or roof opening around the cap.

Install Range Hood

1.Remove terminal box cover.

2.For vented model installations only:A

A. Terminal box cover

2.For vented model installations only:

Remove either top or rear rectangular vent knockout. Install vent connector/damper using the 2 - #8B sheet metal screws provided.

3.Depending on your installation, remove either back or top wiring hole knockout.

C

A

CB

A. Wiring hole knockouts

B. Vent knockouts

C. #8B sheet metal screws

NOTE: If the wall cap is directly behind the vent connector/ damper, the damper in the connector and wall cap must not interfere with each other. Remove the vent connector damper if it interferes.

4.Lift the range hood up under cabinet and determine final location by centering beneath cabinet. Mark on the underside of cabinet the location of the 4 keyhole mounting slots on the range hood. Set range hood aside on a covered surface.

A

A. Keyhole slot

5.Use ¹⁄₈" (3 mm) drill bit and drill 4 pilot holes as shown.

A

A. Drill pilot hole.

6.Install the 4 - #10 x ⁵⁄₈" mounting screws in pilot holes. Leave about ¹⁄₄" (6.4 cm) space between screw heads and cabinet to slide range hood into place.

¹⁄₄"

(6.4 mm)

CWARNING

Electrical Shock Hazard

Disconnect power before servicing.

Replace all parts and panels before operating.

Failure to do so can result in death or electrical shock.

7.For Direct Wire Installations:

Install a UL listed or CSA approved strain relief.

A

A. UL listed or CSA approved strain relief

Pull about 12" (30 cm) of wire through wall or cabinet and into opening.

For Power Supply Installations:

Follow instructions included with power supply cord kit marked for range hoods.

9

Page 9
Image 9
Maytag 99043751D Install Range Hood, C A Cb, For vented model installations only, For Direct Wire Installations