Maytag MDB6709AWW Connect drain hose, Waste disposer - with air gap, Waste disposer - no air gap

Models: MDB6709AWW W10290309A

1 40
Download 40 pages 61.08 Kb
Page 9
Image 9
3 Connect drain hose

3 Connect drain hose

Connect drain hose to waste tee or waste disposer

Option C, Waste disposer – with air gap

Waste disposer – with air gap

using one of the following options:

Option A, Waste disposer - no air gap

Option B, No Waste disposer - no air gap

Option C, Waste disposer - with air gap

Option D, No waste disposer - with air gap

IMPORTANT: The drain hose connection of the disposer or a waste tee must be made before the drain trap and at least 20" (50.8 cm) above the floor where the dishwasher will be installed.

Screw-type clamps

Disposer inlet

Option C, Waste disposer – with air gap Air gap

Large silver drain hose clampl (provided)

Rubber hose connector

Drain hose

Helpful Tip: To reduce vibration of the hose, keep the hose away from the floor.

Option A, Waste disposer – no air gap

Drain trap

Waste disposer – no air gap

Disposer inlet

 

Large silver

 

drain hose clamp

 

 

Drain hose

 

 

 

Drain trap

1

1. Using a hammer and screwdriver, knock

plug into disposer.

1Waste disposer – with air gap

2Option A, Waste disposer – no air gap

3Black end

4

1. Using a hammer and screwdriver, knock

plug into disposer.

2. Use needle-nose pliers to remove plug.

3. Connect black end of drain hose to air gap

and cut if needed.

NOTE: Do not cut ribbed section.

4. Attach drain hose to air gap with large

silver drain hose clamp (provided). Use

pliers to squeeze clamp open and move

into position. If the drain hose was cut, use

a 1¹⁄₂" to 2" (3.8 to 5 cm) screw-type clamp

2

2. Use needle-nose pliers to remove plug.

3. Attach drain hose to disposer inlet with

5

(not provided).

5. Use a rubber hose (not provided) with

screw-type clamps (not provided) to

connect from air gap to disposer inlet.

3large silver drain hose clamp (provided). Use pliers to squeeze clamp open and move into position.

Option B, No waste disposer – no air gap

No waste disposer – no air gap

 

ScrewLarge-silvertype

 

drain clamphose clamp

 

Waste tee

 

Drain hose

 

Drain trap

1 Black end

1. Connect black end of of drain hose to waste

tee and cut if needed.

 

NOTE: Do not cut ribbed section.

2

2. Attach black end of drain hose to waste tee

with a large silver drain hose clamp (provided).

Use pliers to squeeze clamp open and move

 

 

into position. If the drain hose was cut, use a

 

1¹⁄₂" to 2" (3.8 to 5 cm) screw-type clamp (not

 

provided).

Option D, No waste disposer – with air gap

No waste disposer – with air gap

Air gap

Screw-type clamps

Large silver drain

 

hose clamp

 

(provided)

Waste tee

Rubber hose

 

connector

 

Drain hose

 

Drain trap

1 Black end

1. Connect black end of drain hose to air gap

 

and cut if needed.

 

 

 

 

NOTE: Do not cut ribbed section.

 

 

 

 

2. Attach drain hose to air gap with large silver

 

 

 

 

 

2

 

 

drain hose clamp (provided). Use pliers to

 

 

 

squeeze clamp open and move into position.

 

 

 

If the drain hose was cut, use a 1¹⁄₂" to 2"

 

 

 

 

(3.8 to 5 cm) screw-type clamp (not

 

 

 

 

provided).

 

3

 

 

3. Use a rubber hose (not provided) with

 

 

 

 

screw-type clamps (not provided) to

 

 

 

 

connect from waste tee to air gap.

9

Page 9
Image 9
Maytag MDB6709AWW, W10290309A Connect drain hose, Waste disposer - with air gap, Waste disposer - no air gap