Electrical Connection
Power Supply Cord
WARNING
Fire Hazard
use a new ul listed 30 amp power supply cord. use a ul listed strain relief.
Disconnect power before making electrical connections.
Connect neutral wire (white or center wire) to center terminal (silver).
Ground wire (green or bare wire) must be connected to green ground connector.
Connect remaining 2 supply wires to remaining 2 terminals (gold).
Securely tighten all electrical connections.
Failure to do so can result in death, fire, or electrical shock.
Direct Wire
WARNING
Fire Hazard
Use 10 gauge solid copper wire. Use a UL listed strain relief.
Disconnect power before making electrical connections.
Connect neutral wire (white or center wire) to center terminal (silver).
Ground wire (green or bare wire) must be connected to green ground connector.
Connect remaining 2 supply wires to remaining 2 terminals (gold).
Securely tighten all electrical connections.
Failure to do so can result in death, fire, or electrical shock.
Electrical Connection Options
1. Choose electrical connection type
Power supply cord
Power supply cord
Then go to Venting Requirements.
then steps
NOTE: If local codes do not permit connection of a
2. Remove terminal block cover
C | B | A |
|
| D |
|
| E |
|
| F |
Before you start, disconnect power. Remove
A. Terminal block cover
B. External ground conductor screw
C. Center,
D.
E. Neutral ground wire
F. Hole below terminal block cover
7