MB QUART REF1.800, REF4.50, REF4.80 installation manual Linking Mono Amplifiers, Mono Subwoofer

Models: REF1.800

1 11
Download 11 pages 62.15 Kb
Page 8
Image 8
Linking Mono Amplifiers

REF1.800

Linking Mono Amplifiers

DUAL AMP INSTALLATION PROCEDURE:

1.Connect the amp LINE INPUTS to the Radio/CD player full range or mono line out puts with good quality RCA interconnect cables.

2.Plug the MBQR-2 level remote module into the amp REMOTE INPUT jack on the Master amp. This will allow the Master amp to control both Master and Slave amps with just one Remote.

3.Connect an RCA jumper cable from the Master amp MASTER OUTPUT to the Slave amp SLAVE INPUT. Note: This will “link” the amps so that the Master amp crossover switches will control both the Master and Slave amps. The Slave amp crossover switches will be bypassed.

4.Make sure that the MASTER amps’ MODE switch is in the Master Out position. Next you need to make sure that the SLAVE amps’ MODE switch is in the Slave In position.

5.Route two 4 gauge power cables directly to the vehicle battery with an in-line fuse.

6.Connect two 4 gauge ground cables directly to the chassis with in 36” of the amp.

-Be sure to remove any paint or primer from the ground point.

-Use a nut, bolt and lock washer to secure the ground cable to the chassis ground.

7.Connect the subwoofer(s) in accordance to the diagrams below.

8.Connect a 12 gauge jumper from Master amp speaker - to Slave amp speaker - as shown below.

IMPORTANT: Please understand that each amplifier is stable to 1 Ohm, but when linking a pair as indicated below you can not link below 2 Ohms. You can successfully run one DVC 4 Ohm sub, two SVC 4 Ohm subs or two DVC 2 Ohm subs to get your 2 Ohm final load.

MIN MAXX

MBQR-2

DESIGNATED

MONO OUTPUT FROM HEAD UNIT

Slave Master In Out

MODE

 

 

REMOTE

 

0dB 12dB

BOOST

BASS

15Hz 55Hz

SUBSONIC

 

40Hz

LOW

 

150Hz

PASS

 

5V 0.2V

LEVEL

 

 

R

 

 

INPUT

 

Slave In

Master Out

 

MODE

Slave Master

In Out

OUT MONO

IN

OUTPUT

+

 

 

+

 

 

 

SPEAKER

-

 

 

-

 

 

 

 

 

 

 

 

 

 

FUSE

 

POWER INPUT

GND REM BATT+12V

POWER

PROTECT

MONO

SUBWOOFER

 

 

 

 

Slave Master In Out

MODE

Slave Input onSlaveamplifier

on MasterAmplifierto

Single RCA fromMasterOutput

 

0dB 12dB 15Hz 55Hz 40Hz150Hz5V0.2V

REMOTE

L

BASS SUBSONIC INPUTLEVELLOWPASS R

 

 

 

 

 

BOOST

 

 

 

In

Slave

Master Out

MODE

Slave Master

In Out

OUT

IN

OUTPUT

+

 

 

+

 

 

 

SPEAKER

-

 

 

-

 

 

 

 

 

 

 

 

 

 

FUSE

 

POWER INPUT

GND REM BATT+12V

POWER

PROTECT

7

Page 8
Image 8