ASSEMBLING THE

HEAVY-DUTY STEAM CLEANER

ATTACHING UTILITY BRUSHES

WARNING: Do not try to connect accessories while unit is emitting steam.

This section applies to all Utility Brushes. Note that Utility Brushes attach to Steam Jet Nozzle, not to main steam nozzle.

1.Align guide tab on inside of Utility Brush (FIGURE 3-A) with groove on bottom of Steam Jet Nozzle tip (FIGURE 3-B), and firmly press Utility Brush onto Steam Jet Nozzle.

2.Press Utility Brush as far on to Steam Jet Nozzle as possible to ensure that it is properly sealed, to help prevent any steam leakage (FIGURE 4).

3.To remove Utility Brush, simply grip it firmly and pull it off of Steam Jet Nozzle.

USING THE

HEAVY-DUTY STEAM CLEANER

FILLING WATER RESERVOIR WITH WATER

1.

Place Steam Cleaner on a flat, level surface.

2.

Make sure Lighted On/Off Switch is set to “Off” position and grounded power cord is

 

unplugged from electrical outlet.

3.

Press and hold Steam Button to ensure that any remaining steam has been emitted from

 

unit.

4.

Flip up Storage Compartment lid. Cautiously unscrew and remove Water Reservoir

 

cap.

5. Water Reservoir should always be emptied after each use. If it was not emptied after

 

the last use, empty it now. This will prevent over-filling.

6.

Fill Measuring Cup to maximum fill line (16 oz. / 473 ml.) with water.

 

NOTE: To prolong the life of your Steam Cleaner, we recommend using distilled

 

or de-mineralized water.

7.

Carefully pour water from Measuring Cup into Water Reservoir through fill hole.

 

WARNING: Extreme caution should be used when pouring water into the Water

 

Reservoir. Do not look directly down into fill hole when filling. Keep your free

 

hand and any children or pets at a safe distance.

FIGURE 3

ATTACHING SCRUB PAD

This section applies to the Scrub Pad. Note that Scrub Pad attaches to Steam Jet Nozzle, not to main steam nozzle.

1.Place Scrub Pad over tip of Steam Jet Nozzle, and firmly press it as far on to Steam Jet Nozzle as possible to ensure that it is properly sealed (FIGURE 5). This will help prevent any steam leakage.

2.To remove Scrub Pad, simply grip it firmly and pull it off of Steam Jet Nozzle.

FIGURE 4

FIGURE 5

8. Depending on how long you intend to steam, you may repeat steps 6 & 7 up to two

more times, to have up to a maximum of 48 oz. (1,420 ml.) of water. See chart for a

comparison of the amount of water vs. approximate steam time.

9.Replace Water Reservoir cap, ensuring that it is screwed on tightly to prevent hot steam from escaping and causing injury.

10.Lower Storage Compartment lid back down.

8

9

Page 8
Image 8
McCulloch 8823 manual Attaching Utility Brushes, Filling Water Reservoir with Water, Attaching Scrub PAD