| SWITCH | TONE | Nom O/P |
| TONE FREQ/DESCRIPTION | SETTING | DESCRIPTION | (dB(A) |
|
| 12345 |
| @1M) |
1 | Alt Tones 800/970 Hz at 1/4 sec | 11111 |
| 114 |
2 | Sweeping 800/970 Hz at 7Hz | 11110 | Fast Sweep(LF) | 114 |
3 | Sweeping 800/970 Hz at 1 Hz | 11101 | Med Sweep(LF) | 114 |
4 | Continuous at 2850 Hz | 11100 |
| 109 |
5 | Sweeping | 11011 | Fast Sweep | 114 |
6 | Sweeping | 11010 |
| 114 |
7 | Slow Whoop | 11001 | Slow Whoop | 115 |
8 | Sweep | 11000 | Din Tone | 115 |
9 | Alt Tones 2400/2850 Hz at 2 Hz | 10111 |
| 111 |
10 | Int Tone of 970 Hz at 1 Hz | 10110 | 114 | |
11 | Alt Tones 800/970 Hz at 7/8 Hz | 10101 |
| 114 |
12 | Int Tone at 2850 Hz at 1Hz | 10100 | Back Up Alarm(HF) | 109 |
13 | 970Hz at 1/4 sec on 1 sec off | 10011 |
| 114 |
14 | Continuous at 970 Hz | 10010 |
| 114 |
15 | 554Hz for 100mS / 440 Hz for 400mS | 10001 | French Fire Sound | 101 |
16 | Int 660 Hz 150 mS on 150 mS off | 10000 | Swedish Fire Alarm | 106 |
17 | Int 660 Hz 1.8 sec on 1.8 sec off | 01111 | Swedish Fire Alarm | 106 |
18 | Int 660 Hz 6.5 sec on 13 sec off | 01110 | Swedish Fire Alarm | 104 |
19 | Continuous 660 Hz | 01101 | Swedish Fire Alarm | 106 |
20 | Alt 554/440 Hz at 1 Hz | 01100 | Swedish Fire Alarm | 100 |
21 | Int 660 Hz at 7/8 Hz | 01011 | Swedish Fire Alarm | 106 |
22 | Int 2850 Hz 150 mS on 100 mS off | 01010 | Pelican Crossing | 109 |
23 | Sweep | 01001 | Low Freq Buzz | 113 |
24 | Sweep | 01000 | High Freq Buzz | 112 |
25 | 3 970Hz pulses 0.5on/0.5off, 1.5 off | 00111 |
| 113 |
26 | 3 2850Hz pulses 0.5on/0.5off, 1.5 off | 00110 |
| 109 |
27 | Int 3100 Hz 0.32s on / 0.68s off | 00101 |
| 110 |
28 | Spare/Customer Tone | 00100 |
|
|
|
|
|
|
|
29 | Spare/Customer Tone | 00011 |
|
|
30 | Spare/Customer Tone | 00010 |
|
|
31 | Spare/Customer Tone | 00001 |
|
|
32 | Spare/Customer Tone | 00000 |
|
|
|
|
|
|
|
06/01 |
|
|
| © MEDC 2001 |
|
|
|
|
|