the machine or components thereof are damaged.
there are any leaks.
the minimum volumetric control (pressure gauge) is functioning correctly.
Suction performance check.
The following general inspections should be carried out on an annual basis:
Visual inspection to determine whether
the filter is OK (dust indicator).
the machine or components thereof are damaged.
there are any leaks.
the minimum volumetric control (pressure gauge) is functioning correctly.
Suction performance check.
A log for annual general inspections should be kept. This must clearly show the date of the inspection, identified faults and the name of the inspector. If required, the machine should undergo an overhaul!
15 Overhaul
If required, an overhaul must be carried out. Written records should be made of the work carried out during the overhaul.
16 Repairs
Repairs to the dust extractor should only be carried out by qualified technicians!
Machines requiring repairs can be sent to the address specified on the
17 Environmental Protection
Packaging is 100% recyclable.
These operating instructions are printed on
18 Technical Specifications
Changes due to technological progress reserved.
The stated technical specifications are subject to tolerances (as specified in the respective current standards).
SPA 2002 W |
|
|
Operating mode: |
| Continuous operation |
Current type: | ||
Frequency: |
| 50 Hz |
Rated consumption: | P1=1.47 kW | |
Output performance: | P2=1.1 kW | |
Mains voltage: |
| ~230 V |
Power consumption: | 6.4 A | |
Degree of protection: | IP 54 | |
Idling speed: |
| 2830 rpm |
Diameter of extractor connection piece: 100 mm
Dimensions: | 1085 x 655 x 1974 mm | |
Weight: |
| 97 kg |
Filtering surface: |
| 3.45 m2 |
Dust collection volume: | 135 l | |
Rated volumetric flow: |
| Vrat = 775 m3/h |
Related vacuum: |
| 2095 Pa |
(upstream of ventilator) |
| |
Minimum volumetric flow: | Vmin = 565 m3/h | |
Related vacuum: |
| 1572 Pa |
(upstream of ventilator) |
|
ENGLISH
Max. volumetric flow: | Vmax = 1038 m3/h |
Max. vacuum: | 2430 Pa |
Typical
Sound output level: Wear ear protection!
Sound level as per MRL, Appendix 1, Point 1.7.5 f, in free field, distance 1 m, height 1.6 m.
Measured values determined in conformity with EN 23744.
SPA 2002 D |
|
|
Operating mode: |
| Continuous operation |
Current type: | ||
Frequency: |
| 50 Hz |
Rated consumption: | P1=1.57 kW | |
Output performance: | P2=1.16 kW | |
Mains voltage: |
| 400 V |
Power consumption: | 3.4 A | |
Degree of protection: | IP 54 | |
Idling speed: |
| 2890 rpm |
Diameter of extractor connection piece: 100 mm
Dimensions: | 1085 x 655 x 1974 mm | |
Weight: |
| 97 kg |
Filtering surface: |
| 3.45 m2 |
Dust collection volume: | 135 l | |
Rated volumetric flow: |
| Vrat = 775 m3/h |
Related vacuum: |
| 2095 Pa |
(upstream of ventilator) |
| |
Minimum volumetric flow: | Vmin = 565 m3/h | |
Related vacuum: |
| 1572 Pa |
(upstream of ventilator) |
| |
Max. volumetric flow: |
| Vmax = 1038 m3/h |
Max. vacuum: |
| 2430 Pa |
Typical
Sound output level: Wear ear protection!
Sound level as per MRL, Appendix 1, Point 1.7.5 f, in free field, distance 1 m, height 1.6 m.
Measured values determined in conformity with EN 23744.
11