Serial Configuration

The IS4920 series can be configured by scanning configuration bar codesor by serial commands sent from the host device. With serial configuration, each command sent to the engine is the ASCII representation of each numeral in the configuration bar code (see Figure 19). The entire numeric string is framed with an ASCII [stx] and an ASCII [etx].

Do Not Include

³ 1 0 0 1 0 4

Include in the

in the Command

 

 

Command

 

 

 

 

Figure 19.

 

 

 

Example 1:

 

 

Feature

Host Command

String Sent to the Engine - ASCII Representation (Hexadecimal Values)

Disable Codabar

[stx]100104[etx]

02h 31h 30h 30h 31h 30h 34h 03h

 

 

 

If the command sent to the engine is valid, the engine will respond with an [ack]. If the command sent to the engine is invalid, the engine will respond with a [nak] then automatically exit serial configuration mode. All the settings chosen in the failed serial configuration session will be lost. There is a 20-second window between commands. If a 60-second timeout occurs, the engine will send a [nak].

To enter serial configuration mode, send the following command, [stx]999999[etx]. The engine will not scan bar codes while in serial configuration mode.

Note: Serial configuration mode uses the current Baud Rate, Parity, Stop Bits and Data Bits settings that are configured in the engine. The default settings of the engine are 9600 bits-per-second, no parity,

1 stop bit, 8 data bits, and no flow control. If a command is sent to the engine to change any of these settings, the change will not take effect until after serial configuration mode is exited.

To exit serial configuration mode, send the following command, [stx]999999[etx]. The engine will respond with an [ack]. Refer to Example 2 on page 23.

Bar code configuration manuals are available for download from the IS4920 product page at www.honeywell.com/aidc.