7
INTRODUCTION
MS2220 SCANNER/AVERY SCALE DESIGN SPECIFICATIONS
Design Specifications
Scale Capacities
Capacity: kg unit 15 kg lb. unit 30.0 lb.
Minimum Increment: kg unit 0.005 kg lb. unit 0.01 lb.
Maximum Static Weight: kg unit 75 kg
lb. unit 150 lb.
Adjustments required: Calibration is required for scaled units.
Electrical
Voltage Supply: 2A @ +5.2V / 1A @ +12V
Operating Power: 11.9 Watts
Standby Power: 3.25 Watts
Operating Current: 1.5A @ 5.2V / .3A @ 12V
Standby Current: .44 A @ 5.2V / .08A @ 12V
DC Transformers: Class II; 5.2VDC @ 2A; 12VDC @ 1A
For Regulatory Compliance Information refer to pages 73 - 75.
Environmental
Operating Temperature: 0°C to 40°C (32°F to 104°F)
IP Rating: IP 55
Light Levels: 4842 Lux (450 footcandles)
Storage Temperature: -40°C to 60°C (-40°F to 140°F)
Humidity: 5% to 95% Relative Humidity, Non-Condensing
Contaminants: Sealed to resist airborne particulate contaminants.
Ventilation: None Required
Specifications are subject to change without notice.