 37
SCANNER OPERATION 
INDICATOR DESCRIPTIONS 
Diagnostic Indicator Display 
ERROR 
CODE DESCRIPTION 
25 
LASER #2 (RIGHT HORIZONTAL) HIGH CURRENT WARNING – The laser in the vertical scanning subsystem is 
drawing excessive current.  This could be a warning for a future total failure.  Have the unit checked at an 
authorized service center when convenient. 
26 
LASER #3 (LEFT HORIZONTAL) HIGH CURRENT WARNING – The laser in the vertical scanning subsystem is 
drawing excessive current.  This could be a warning for a future total failure.  Have the unit checked at an 
authorized service center when convenient. 
27 
LASER #1 (VERTICAL) UNDERCURRENT WARNING – The laser in the vertical scanning subsystem is drawing 
too little current.  The laser is probably not on.  This could be the result of a loss of the required set point in 
memory.  Have the unit checked at an authorized service center. 
28 
LASER #2 (RIGHT HORIZONTAL) UNDERCURRENT WARNING – The laser in the right horizontal scanning 
subsystem is drawing too little current.  The laser is probably not on.  This could be the result of a loss of the 
required set point in memory.  Have the unit checked at an authorized service center. 
29 
LASER #3 (LEFT HORIZONTAL) UNDERCURRENT WARNING – The laser in the left vertical scanning 
subsystem is drawing too little current.  The laser is probably not on.  This could be the result of a loss of the 
required set point in memory.  Have the unit checked at an authorized service center. 
31 
MOTOR #1 (VERTICAL) ERROR – The motor in the vertical scanning subsystem denotes a failure.  The scanner 
will try three times to correct the motor operation.  If the motor error persists, the vertical scanning subsystem will 
be shut down and this error code will remain on the Diagnostic Indicators.  
32 
MOTOR #2 (HORIZONTAL) ERROR – The motor in the horizontal scanning subsystem denotes a failure.  The 
scanner will try three times to correct the motor operation.  If the motor error persists, the horizontal scanning 
subsystem will be shut down and this error code will remain on the Diagnostic Indicators.  
34  MOTOR #1 (VERTICAL) SPEED ERROR – The motor in the vertical section cannot be speed controlled as 
desired.  Have the unit checked at an authorized service center. 
35  MOTOR #2 (HORIZONTAL) SPEED ERROR – The motor in the horizontal section cannot be speed controlled as 
desired.  Have the unit checked at an authorized service center.