22
TROUBLESHOOTING GUIDE

The following guide is for reference purposes only. Contact a Metrologic

representative at 1-800-ID-METRO or 1-800-436-3876 to preserve the

limited warranty terms on page 39.

All Interfaces

MS7120 Series Troubleshooting Guide

SYMPTOMS POSSIBLE CAUSE(S) SOLUTION
No LEDs, beep
or motor spin No power is being
supplied to the
scanner
Check transformer, outlet and
power strip. Make sure the
cable is plugged into the
scanner
No LEDs, beep No power is being
supplied to the
scanner from host
Some host systems cannot
supply enough current to power
Orbit. Use the power supply
included with the scanner.
3 beeps on
power up Non-volatile RAM
failure Contact a Metrologic
Representative, if the unit will
not hold the programmed
configuration
Continuous
razz tone on
power up
RAM or ROM failure Contact a Metrologic
Representative, if the unit will
not function
Razz tone and
green LED
flash at power
up
VLD failure Contact a Metrologic
Representative
Razz tone and
both LEDs flash
at power up
Scanner motor failure Contact a Metrologic
Representative
Unit scans,
Communicates
and beeps
twice
Same symbol timeout
set too short Adjust same symbol timeout for
a longer time