28
Applications and Protocols
The model number on each scanner includes the scanner number and
communications protocol.
Scanner Version Identifier Communication Protocol(s)
7120 41 Full RS-232C and Light Pen Emulation
7120 47 Keyboard Wedge, Stand-Alone Keyboard
and RS-232 Transmit/Receive
7120 9 OCIA and RS-232 Transmit/Receive
7120 11 IBM 46XX and Full RS-232C
7120 67 Full RS-232C
The MS7120 Hand-Held Laser Scanner with Built-in PC Keyboard
Wedge Interface is designed to be used for keyboard emulation only. However,
many RS-232 programmable functions that are available
in other Metrologic scanners are also available as keyboard wedge functions.
The most important selectable options specific to the key-
board wedge are the following:
Keyboard Type
!** AT (includes IBM PS2 models 50, 55, 60, 80)
®
!XT
!IBM PS2 (includes models 30, 70, 8556)
Keyboard Country Type
!** USA !United Kingdom
!French !German
!Italian !Spanish
!Belgium !Swiss
**Default setting. Refer to Appendix B pages 31-35 for default settings.
Refer to the MetroSelect Programming Guide (MLPN 2407) for infor-
mation on how to change the default settings.