INSTALLATION OF AN AUXILIARY SCANNER

11. Configure the auxiliary scanner to send formatted data to the MS7220.
Normal slave mode operation will only require reserve Code 32 to be
set in the auxiliary scanner. The following bar code applies for all
scanners, except the MS6720, to be used as an auxiliary scanner.
Contact a Metrologic representative for information on the MS6720.
12. Configure the MS7220 to activate the auxiliary port. Enable the
auxiliary port and configure it to recognize slave formatted data with the
following bar code:
13. Turn on the host system.
³124817
Reserve Code 32
³437330
Enable Aux Port
Figure 6: Auxiliary Scanner Setup