MS7580 Genesis Technical Specifications
Operational
Light Source | Visible Laser Diode 645 nm ± 7.5 nm |
Audible Indicators | 7 tones or no beep |
Visual Indicators | Blue = ready to scan; White = good read |
Host System Interfaces | USB, RS232, Keyboard Wedge, IBM 46xx (RS485) |
Auxiliary Ports | EAS with interlock (EAS model) |
Mechanical |
|
Dimensions (LxWxH) | 80 mm x 83 mm x 150 mm (3.2˝ x 3.3˝ x 5.9˝) |
Weight | 340 g (12 oz) |
Electrical |
|
Input Voltage | 12 VDC ± 0.25 V |
Operating Power | 2.3 W (192 mA @ 12 V) - typical |
Standby Power | 1.7 W (142 mA @ 12 V) - typical |
DC Transformers | Class 2: 12 VDC @ 1.25 A |
LED Class | Class 1: |
EMC | FCC Part 15, |
Environmental
Operating Temperature
Storage Temperature
Humidity
Drop
Environmental Sealing
Light Levels
Scan Performance
Scan Pattern
Sensor Resolution
Motion Tolerance
Scan Angle
Print Contrast
Tilt, Pitch, Skew
Decode Capability
0°C to 40°C (32°F to 104°F)
0% to 95% relative humidity,
Sealed to resist airborne particulate contaminants 100,000 Lux (9,290
Area
1.3 megapixel
200 cm/s (78 in/s) for 13 mil UPC @ 10 cm (4˝) distance Horizontal: 46°; Vertical: 28°
20% minimum reflectance difference 360°, 70°, 75°
1D: Code 39, Code 93, Code 128, UPC/EAN/JAN, Code 2 of 5, Code 11, Codabar, MSI Plessey, GS1 DataBar, Telepen, Trioptic
*PDF: PDF417, MicroPDF417
*2D: QR Code, Micro QR Code, Data Matrix, Aztec Code, Maxicode, Codablock, Composite Code, POSTNET, PLANET, UPU, Intelligent Mail, Canada Post, Australia Post, Japanese Post, Royal Mail RM4SCC, KIX Code *OCR:
RoHS |
2002/95/EC |
For more information:
www.honeywell.com/aidc
Security & Data Collection
Honeywell Scanning & Mobility Honeywell
90 Coles Road Blackwood, NJ 08012 856.228.8100
Wall mount
MLPN
| Typical Performance* |
|
|
Narrow Width | Depth of Field |
5.2mil (1D) 40 mm - 80 mm (1.6˝ - 3.1˝)
7.5mil (1D) 30 mm - 120 mm (1.2˝ - 4.7˝)
10.4mil (1D) 20 mm - 140 mm (0.8˝ - 5.5˝)
13 mil (1D) 0 mm - 152 mm (0˝ - 6.0˝)
10.0 mil (PDF) | 0 mm - 120 mm (0˝ - 4.7˝) |
15.0 mil (PDF) | 30 mm - 120 mm (1.2˝ - 4.7˝) |
*Resolution: 4 mil (0.102 mm) *Performance may be impacted by bar code quality and environmental conditions
www.honeywell.com
© 2008 Honeywell International Inc.