 17
CONFIGURING FOR USB SERIAL EMULATION (MX009-2XX8X) 
MS6720, MS860, AND TECH SERIES 
These Metrologic scanners must be reconfigured using the following bar codes 
before the MX009 can communicate properly with a host system. 
• MS6720   • MS860   • Tech Series 
Note:   Configuration for USB Serial Emulation must be completed before 
enabling/disabling any additional features documented in the 
configuration guide provided with the scanner. 
Important:  When enabling/disabling additional features do not scan the 
Recall Defaults bar code.  If the Recall Defaults bar code is 
scanned, all USB Serial Emulation configurations will be 
lost and the process will have to be restarted. 
Scan the following bar codes in numbered sequence. 
1. 
ENTER/EXIT 
CONFIGURATION MODE 
0  12345 66666  7 
 2.  
RECALL DEFAULTS 
0  12345 66661  2 
3. 
ENABLE RS232 MODE 
0  12345 30955  7 
Continued on next page.