Appendix B (Continued)
Version "15" Pin Assignmentsfor Light Pen Emulation
Each TECH 7 scanner has a 19-pin male Mil spec connector that is
located on the side of the unit. To connect the scanner to the host
device, use a communication cable with a female Mil spec connector.
The communication cable may include a power supply or it may be
designed to draw power directly from the host device. This item can
be ordered when the scanner is purchased.
The Version "15" scanner is designed to be used for Light Pen
Emulation communication.
The following is a list of pin assignments. The pin numbers are
impressed on the male Mil spec connector. For easier reference, refer
to Figure 10 for pin locations.
Pin Function
A R Data
B Light Pen Data Output
C Signal Ground
D Light Pen Source & 5 VDC
E R Data Return
F RS-232 Output
G Clock in
H Clock in Return
J Clock Out
K Shield Ground
L DTR Input
M Clock Out Return
N Power to Scanner & 24 VDC
P Earth Ground
R Power Ground
S RS-232 Input
18
NB
JTU
K
A
L
M
PC
HSRD
GFE
Figure 10: Pin Locations