16
Complementary power MOSFET output stages class AB/H
1240 Watts (620 Watts/channel)
< .02 %

Acoustical

Copyright © 1997 Meyer Sound Laboratories, Inc.
All rights reserved
Part # 05.041.010.01 Rev A
±4 dB 40 Hz – 18 kHz
±90° 50 Hz – 16 kHz
CQ-1: 136 dB ; CQ-2: 139 dB
> 110 dB

Specifications

Frequency Response1
Phase Response1
Maximum Peak SPL1
Dynamic Range2

Coverage

CQ-1

–6 dB points
–10 dB points
–6 dB points
–10 dB points

CQ-2

CQ-1
CQ-2

Acoustical Crossover Point

Transducers

Low Frequency
High Frequency

Audio Input

Type
Connector
Nominal Input Level

Amplifiers

Type
Burst Capability3
THD, IM, TIM

AC Power

Connector
Automatic voltage selection4
Max Continuous RMS Current (> 10 s)
Max Burst RMS Current (< 1 s)
Max Peak Current During Burst
Soft Current Turn-on

Physical

Dimensions
Weight
Enclosure/Finish
Protective Grill
Rigging
10 k impedance, electronically balanced
XLR (A-3) male and female
+4 dBu (1.23 Vrms)
H: 50° (800 Hz – 12 kHz); V: 40° (1.5 kHz – 12 kHz)
H: 60° (800 Hz – 12 kHz); V: 50° (1.5 kHz – 12 kHz)
15” diameter MS-15 cone
4” diaphragm MS-2001CQ horn compression driver
250 V NEMA L6-20P / IEC 309 Twistlock male receptacle
85 – 134 V / 165 – 264 V; 50 Hz / 60 Hz
115 V: 8 A 230 V: 4 A 100 V: 10 A
115 V: 15 A 230 V: 8 A 100 V: 18 A
115 V: 22 Apk 230 V: 11 Apk 100 V: 25 Apk
Inrush current < 12A @115V
21” W x 30” H x 22 12” D
130 lb (59 kg); shipping: 150 lb (68 kg)
All birch plywood/black textured
Perforated steel grill, charcoal-grey foam
Four aircraft pan fittings (two on top and bottom).
Working load for each fitting is 500 lb (15 the cabinet
breaking strength) with straight tensile pull.
H: 80° (500 Hz – 16 kHz); V: 40° (1.5 kHz – 12 kHz)
H:100° (500 Hz – 16 kHz); V: 50° (1.5 kHz – 12 kHz)
700 Hz
900 Hz

Notes

1. Subject to half-space loading; measured
with one-third octave frequency resolution
in fixed ISO bands.
2. Measured as the ratio between the peak
SPL and the A-weighted noise floor.
3. Nominal 8
resistive load, pink noise,
100 V peak.
4. The unit is rated at 88 – 125 VAC and
182 – 235 VAC, 50/60 Hz, to satisfy EC
standards for –10% to 6% AC line voltage.