MGE UPS SYSTEMS Pulsar ESV 8+/11+/14+/22+ EB 22/EB 22XLA :86-153277-00 13
option 1
■status information card:after the card is
installed in the rear of the Pulsar, communi-
cation port 15 transmits status information
on a SUB-D 9-pin female connector using
the following pinouts:
1-ground,
4-normal operation,
5-common,
7-low battery warning,
9-operation on battery.
communicationThe communication port 9, at the rear of
Pulsar, delivers information in the form of
an RS232 serial link supported by the com-
munication protocol exclusive to
MGE UPS SYSTEMS.The Solution-Pac
programs use the data made available by
this protocol.
9
V
I
54321
9876
0V RD TD
1 - ground
2 - TD
3 - RD
5 - common
ESV Driver software (included in the
CD-ROM:EMB/ESVPLUS/CONFIG) lets
you edit the default parameter of Pulsar:
■battery test frequency
(default:every week);
■nominal output voltage
(default:120 Volts);
■high/low voltage thresholds
(defaut:138/92 Volts);
■Fader/Booster activation thresholds
(defaut :102/128 Volts);
■on/off conditions:
■■automatic restart,
■■forced reboot,
■■energy saving,
■■cold start.
15
n.o.
n.c. n.o.
54321
9876
0V
0V 0V
Relay breaking capacity:
Vmax = 25V DC, Imax = 10mA
n.o.: normally open,
n.c.: normally closed.
option 2
■SNMP card: after the card is installed in
the rear of the Pulsar, communication port
15 transmits information supported by the
SNMP protocol on an RJ45 or BNC
connector.
option 3
■battery extension module Pulsar EB
22XLA (for Pulsar ESV 22+):
Switch off Pulsar ESV 22+ (push
button 3 ), disconnect the input
connection cord 5 .
Connect battery connection cord 19
(included with Pulsar EB 22XLA) to Pulsar
EB 22 and connect to Pulsar EB 22XLA.
You can connect 7 Pulsar EB 22XLA in
parallel.
Contact your retailer for further details.