Operation and Installation Instructions

691 LOCK SYSTEM

READ GENERAL INSTALLATION GUIDELINES SHEET (FORM NO. 81-600-001) BEFORE PROCEEDING.

1. The MICO 691 System is a supplemental safety

6.

Do not use sealants, tapes, teflon or cement

device which provides additional brake holding

 

compounds on any connections or fittings. These

action when used with existing vehicle parking

 

sealants or compounds can contaminate the

brake. It is not for dynamic service braking.

 

hydraulic brake system and interfere with the

2. The 691 System must be used in combination with

 

operation of brake components or MICO 691

an audible and/or visual alarm as a warning to

 

System.

signal the user of any loss of brake system pres-

7.

All fittings and connections must be in good

sure. Do not disconnect warning devices.

 

condition and properly torqued.

3. All lines, fittings and surrounding areas must be

8.

Brake hoses, brake lines, MICO 691 System,

cleaned of dirt or road residue before any lines or

 

brake components, cylinders, and all fittings must

fittings are disconnected. Special care must be

 

be routinely inspected for leaks, damage or wear.

taken so dirt and road residue are not allowed to

 

Proper fluid levels must be maintained. In the

enter the hydraulic brake system. This can con-

 

event of any loss of fluid, brake system must be

taminate the system and interfere with proper

 

carefully inspected for leaks.

operation of brakes and MICO 691 System.

9.

When installation of MICO 691 System is com-

4. Follow procedures outlined in Vehicle Manufac-

 

plete, 691 System and brake system must be

turer’s Service Manual or SAE Standards when

 

bled of air. Bleed MICO 691 System according to

making new connections or adding to existing

 

procedures outlined in this manual. Bleed brake

brake systems. Use only steel brake tubing con-

 

system according to vehicle manufacturer’s

forming to SAE specifications.

 

recommendations.

5. Vehicle Brake System: Always use clean fluid

10.

The self-adhesive warning labels, page 1, ac-

conforming to vehicle manufacturer’s recommen-

 

companying each MICO locking device must be

dations. 691 Power Unit: See BEFORE

 

affixed in the vehicle cab in view of operator.

PROCEEDING, page 3 for proper fluid type.

11.

Keep this manual in the cab of the vehicle after

Improper or contaminated fluid may cause gummy

 

installing the 691 System.

deposits, softening and swelling of rubber seals, and may render the 691 System inoperative. Such a condition must be corrected immediately.

MICO could not possibly know of and give advice with respect to all conceivable applications in which this product may be used and the possible hazards and/or results of each application. MICO has not undertaken any such wide evaluation. Therefore, anyone who uses an application which is not recommended by the manufacturer, first must completely satisfy himself that a danger will not be created by the application selected, or by the particular model of our product that is selected for the application.

MICO has made every attempt to present accurate information in catalogs, brochures and other printed material. MICO can accept no responsibility for errors from unintentional oversights that may exist. Due to a continuous program of product improvement, materials, specifications, and product documentation are subject to change without notice or obligation.

MICO is a registered trademark of MICO, Incorporated. MICO is registered in the U.S. Patent and Trademark Office as well as in Australia, Canada, Great Britain, Indonesia, Japan, Peoples Republic of China, and South Korea.

MICO, Incorporated

MICO West Division

1911 Lee Boulevard (Zip Code 56003-2507)

701 East Francis Street (Zip Code 91761-5514)

P.O. Box 8118 / North Mankato, MN U.S.A. 56002-8118

P.O. Box 9058 / Ontario, CA U.S.A. 91762-9058

￿ 507.625.6426 Facsimile 507.625.3212

￿ 909.947.4077 Facsimile 909.947.6054

Form No. 81-690-032

Revised Online 11/30/06

Printed in U.S.A.