Users Manual & Installation Guide
PV- 1800: Power supply module with GSM MODEM
Installation guide
Precautions to ESD
Please note that the Micronix PV modules must be handled with respect to ESD (Electrostatic Discharge). Electrostatic Discharge to the PV modules must be avoided.
Before removing the module from the protection bag, the user must be discharged using a grounded wrist ribbon.
Settings and connections
A typical setup procedure involves these steps:
1.Perform settings of:
•Base address. (Regs.).
•Port number for COM_A (modem).
•IRQ number COM_A (modem).
•Port number for COM_B (RS232).
•IRQ number for COM_B (RS232).
2.Place module in the PC/104 stack.
3.Connect interface cables: Analogue, digital etc.
4.Place a SIM card in the SIM card connector.
5.Connect the antenna cable to the
6.Connect the power cable (24V DC) at KL1.
Factory settings
The default jumper setting depends on the model you have purchased.
Factory settings,
.
%-
,-
Registers base address: 200h
Modem port: 3E8 (COM3)
Modem IRQ: 10
RS232 port: 2E8 (COM4)
RS232 IRQ: 12
Factory settings,
,-
.
%-
Registers base address: 200h
Modem port: 3E8 (COM3)
Modem IRQ: 10
Page 21 / 21