Electrical connection

Electrical connection 110 V

The appliance is supplied with a power cord and NEMA 5-15 P plug ready for connection to an a.c. single phase

110 V 60 Hz supply (see data plate). The fuse rating is 15 amps.

Electrical connection 208 V or 240 V

The appliance is supplied with a power cord and NEMA 6-20 P plug ready for connection to an a.c. single phase 208 V 60 Hz supply.

The fuse rating is 20 amps.

Wall outlet: NEMA 6-20 R, for a 20 A, 120 V.

,Do not modify the machine power cord or plug, the machine is approved for US and CDN.

All electrical work should be carried out by a qualified electrician in accordance with local and national safety regulations.

Do not connect the rotary iron to an extension cord. Extension cords do not guarantee the required safety of the appliance (e.g. danger of overheating).

Important

If it is necessary to change the plug or power cord of the rotary iron, please take note of the following color codes of the wires:

Green/yellow

= ground

Blue

=

live 1

Brown

=

live 2

WARNING

THIS APPLIANCE MUST BE

GROUNDED