CS 1112 E Ceramic Double Burner CombiSet |
|
Safety distances to back wall
1 – Wall frame
2 – Wall covering
x = thickness of the wall covering 3 – Countertop
4– Countertop
5– Minimum safety distance
with flammable materials 2" (50 mm)
with
If a wall covering is installed, a minimum safety distance must be maintained between the countertop
If the covering is made of a combustible material (such as wood), the distance between the countertop
For coverings made of
For example: thickness of wall covering 9/16" (15 mm) 2" (50 mm) - 9/16" (15 mm) = minimum safety distance 1 3/8" (35 mm).
Safety distances to surrounding cabinetry |
| |
Recommended | Not Recommended | Not Permitted |
The appliance should only be installed as shown in the above illustrations while maintaining the required safety distances shown. Do not install the appliance between two tall cabinets, this is a fire hazard.
A distance of at least 2” (50 mm) must be kept between the countertop and the rear wall because of high temperature radiated.
The minimum distance required from the countertop
Safety distance above the appliance
The minimum safety distance given by the hood manufacturer must be maintained between the combiset and the hood above it. See the installation instructions for the hood for these safety measurements.
If the hood manufacturers instructions are not available or if flammable objects are installed over the combiset (e.g. cabinets, utensil rail, etc.), a minimum safety distance of 30”
Notes (760 mm) must be maintained. |
|
All installations must be done in accordance with local codes. |
|