Miele DA239-3 Installation, Attaching the hood and motor assembly to the wall

Models: DA239-3

1 40
Download 40 pages 4.29 Kb
Page 28
Image 28
Installation

Installation

Attaching the hood and motor assembly to the wall

The chimney and chimney extension are attached to the wall using 2 retaining plates. The motor assembly is attached separately using 4 screws.

To layout the loctaions for the plates and motor assembly:

^Draw a vertical line, centered on the cooktop, on the wall where the hood will be installed.

^Mark the location of the 2 motor assembly support screws S + 10 1/4" (260 mm) above the cooktop, and

4 15/16" (125 mm) to the right and left of the centerline.

^Layout the location of the lower

retaining plate screw directly on the centerline, S + 19 1/2" (495 mm) above the cooktop.

^Hold the upper retaining plate flush against the ceiling so that the centerline passes through the notch on its lower edge. Making sure the plate is level, mark the location of the 2 mounting screws.

28

Page 28
Image 28
Miele DA239-3 installation instructions Installation, Attaching the hood and motor assembly to the wall