Miele DA5341D installation instructions Condensate trap, Air extraction

Models: DA5341D

1 32
Download 32 pages 47.02 Kb
Page 29
Image 29
Condensate trap

Air extraction

If the exhaust is ducted into an inactive flue, the air must be expelled parallel to the flow direction of the flue.

Never connect an exhaust hood to an active chimney, dryer vent, flue, or room venting ductwork. Seek professional advice before connecting an exhaust hood vent to an existing, inactive chimney or vent flue.

Important

If the ductwork runs through rooms, ceilings, garages, etc. where temperature variations exist, it may need to be insulated to reduce condensation.

Condensate trap

optional accessory

In some cases, a 2 condensate traps may be required to collect and evaporate any condensation which may develop. This optional accessory is available for ducts 5" (125 mm) and

5 7/8" (150 mm) in diameter.

^When installing the condensate traps, ensure that they are positioned vertically and if possible directly above the exhaust outlet.

29

Page 29
Image 29
Miele DA5341D installation instructions Condensate trap, Air extraction