Electrical data

Electrical data

All electrical work should be performed by a qualified electrician in strict accordance with national and local safety regulations. Installation, repairs and other work by unqualified persons could be dangerous. The manufacturer can not be held responsible for unauthorized work.

Ensure that power to the appliance is OFF while installation or repair work is performed.

^Verify that the voltage, load and circuit rating information found on the data plate (located behind the grease filter), match the household electrical supply before installing the hood.

^This appliance requires two electrical mains cables. Each one must be connected via a suitable isolator which complies with local and national safety regulations. Their on/off switches must be easily accessible after the appliance has been built in.

If there is any question concerning the electrical connection of this appliance to your power supply, please consult a licensed electrician or call Miele’s Technical Service Department. See back cover for contact information.

WARNING:

THIS APPLIANCE MUST BE GROUNDED

Important

To increase security before the machine is installed, it is recommended to install a protective switch (30 mA).

Important

The hood must be hard wired accordingly:

Black/Red wire:. . . . connect to L1 (live)

White wire: . . . . . connect to N (neutral)

Green wire: . . connect to GND (ground)

Maximum load . . . . . . . . . . . . . . . 820 W Fan. . . . . . . . . . . . . . . . . . . . 2 x 350 W Lighting . . . . . . . . . . . . . . . . . 6 x 20 W

Voltage . . . . . . . . . . . . . . . . . . . . . 120 V

Frequency . . . . . . . . . . . . . . . . . . 60 Hz

Circuit rating. . . . . . . . . . . . . . . . . . 15 A

30