Installation and service must be performed by a qualified installer, service agency or the gas supplier.

In Massachusetts a licensed plumber/gas fitter is required.

This appliance must be installed with its own shut off valve and the included gas pressure regulator. Both the valve and the regulator must be easily accessible to the consumer to turn on or shut off the gas supply after the appliance is installed.

This appliance and its individual shut off valve must be disconnected from the gas supply during any pressure testing of the system performed in excess of 1/2 psi

(3.5 kPa). The machine must be isolated from the gas supply line by closing its individual manual shut off valve at test pressures equal to or less than 1/2 psi (3.5 kPa).

Any pipe connections must be made using a thread sealant approved for gas connections. Failure to correctly install these items could lead to a gas leak and subsequent explosion.

The gas connection must be made in accordance with local codes or in the absence of local codes with:

-the National Fuel Gas Code, ANSI Z 21.1 for the USA

or

-the current Can / CGA Interim #58-M95

and .2 Installation Codes for gas burning appliances for Canada.

Make sure that the maximum gas supply pressure, before the gas pressure regulator, is never more than 1/2 psi (3.5 kPa) for natural gas or LP gas.

The minimum supply pressure to get the required gas input is

6" w.c. for natural gas 10" w.c. for LP gas.