Miele KWT 1601 SF, KWT 1611 SF Side panels, Installation with partition using the Merging Kit

Models: KWT 1611 SF KWT 1601 SF

1 60
Download 60 pages 53.27 Kb
Page 38
Image 38
Installation with partition using the "Merging Kit"

Installation

Installation with partition using the "Merging Kit"

The minimum thickness of the partition is 5/8" (16 mm).

If there is a partition with a thickness

from 5/8" (16 mm) to 6 5/16" (160 mm)

between the adjacent appliances, then each appliance should be individually installed within its own niche using the mounting accessories included.

The "Merging Kit" will also be needed.

The "Merging Kit" is available from Miele.

Installation with partition without using the "Merging Kit"

If there is a partition with a thickness of more than 6 5/16" (160 mm) between the adjacent appliances, then each appliance should be individually installed within its own niche using the mounting accessories included (the "Merging Kit" is not necessary).

Side panels

If one side of the appliance is visible, a side panel must be used.

The side panel must be firmly secured to the wall, the floor and the overhead furniture/fixtures before the appliance is placed in the cavity.

The dimensions of the side panel are taken from the opposite wall of the installation space. During installation, ensure that the cavity is square and the measurements are correct.

Adjusting the door opening angle (optional accessory)

Depending on the installation site, it may be necessary to adjust the door opening angle to 90°.

￿Open the door.

￿Insert the banking pin through the holes and drive in with a hammer.

The door opening angle is now limited to 90°.