J) CHANGING FILTERS

In addition to the dustbag, the vacuum cleaner contains two filters; a central filter that protects the motor (fig.1) and an electrostatic, “Clean Air” filter that removes particles from the exhausted air (fig.2). The Clean Air filter should be changed every six months or whenever it becomes dirty. The central filter should be changed or rinsed out whenever the Clean Air filter is replaced.

Fig. 1

Fig. 2

CENTRAL FILTER (Fig. 1)

Part # F0391100

To remove, slide the central filter forward out of its housing.

IMPORTANT: If the central filter has been rinsed out, make sure it is dry before re-installing it.

CLEAN AIR FILTER (Fig. 2)

Part # S02B0100

To change the Clean Air filter.

1) Remove the dust compartment cover.

2) Slide the filter support out of the bottom of the cover and remove the filter.

IMPORTANT: Do not forget to re-install the filters before use.

TROUBLE SHOOTING GUIDE

Before returning the vacuum cleaner to a Miele Service Center, check the following items:

Problem

Check Point

Cause / Remedy

 

 

 

Motor doesn’t run.

• Cord connection.

• Plug cord into outlet correctly.

(no noise is heard at all)

 

 

 

 

 

Motor runs but no suction.

• Hose inlet clogged.

• I If there is a clog, remove it.

 

• Check the bag change indicator.

• If it shows full, replace the paper

 

 

bag.

 

• Paper bag broken or clogged.

• If the paper bag is broken, replace it.

 

• Central filter.

• If the central filter is full of dust, clean

 

 

or replace it.

 

 

 

Beater bar does not rotate.

• Beater bar selector.

• Select the correct position.

 

• Beater bar / housing.

• If there is an obstruction, remove it.

 

• Belt broken or loose.

• Replace the belt.

 

 

 

8

Page 8
Image 8