Miele T 1520 operating instructions Calculate the effective duct length

Models: T 1520

1 36
Download 36 pages 4.76 Kb
Page 28
Image 28

INSTALLATION INSTRUCTIONS

Calculate the effective duct length

The overall duct length will determine the duct diameter.

^Measure the actual duct length needed:

1.Establish the number of elbows or bends necessary, noting the type of bend, angle and radius involved (see, Table 1).

2.Add the additional duct length as specified in Table 1 to the actual duct length to get the effective duct length.

3.The necessary duct diameter can then be found in Table 2.

Note:

Drying times and energy consumption remain unaltered for 4" (100 mm) duct up to a total length of 66 ft. (20 m). Lon- ger ducts may lead to slight increases, but, the function will not be impaired as long as the necessary duct diameter is used (Table 2).

Table 1

Type

Angle

Radius

Additional

of bend

 

 

 

 

duct length

 

 

inch

 

cm

inch

 

cm

 

 

 

 

 

 

 

 

 

 

 

 

Flexible

90 °

up to

 

40.6

20"

 

50.8

metal duct

 

16"

 

 

 

 

 

 

45 °

up to

 

40.6

12"

 

30.5

 

 

16"

 

 

 

 

 

 

 

 

 

 

 

 

 

Smooth

90 °

4"

 

10

14"

 

35.6

metal duct

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Elbow 90°

90 °

 

 

 

90"

 

228.5

sharp;

 

 

 

 

 

 

 

no radius

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Concertina

90 °

8"

 

20.3

28"

 

71.1

bend

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Wall vent kit

 

 

 

 

142"

 

360.7

with louvres

 

 

 

 

 

 

 

or

 

 

 

 

 

 

 

window

 

 

 

 

 

 

 

vent kit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Wall vent kit

 

 

 

 

99"

 

251.5

with flap or

 

 

 

 

 

 

 

window

 

 

 

 

 

 

 

vent kit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Exhaust

 

 

 

 

193"

 

490.2

connection

 

 

 

 

 

 

 

left side

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table 2

Internal diameter or

 

Effective duct

edge length

 

length

 

 

 

 

 

inches

mm

 

ft

m

 

 

 

 

 

4"

100

0

- 66

0 - 20

5"

125

66

- 100

20 - 30

6"

150

100 - 140

30 - 42.7

 

 

 

 

 

24

Page 28
Image 28
Miele T 1520 operating instructions Calculate the effective duct length, Type Angle Radius Additional Bend Duct length Inch